logofrontpage.GIF (521115 bytes)

Home ] Up ]

Home ] Up ] Installation School ] Northern News Page ] Contact Info ]

Return to this website soon for more detailed information of call (800) 346-5543.

 

 

I. INTRODUCTION: NI-12 "MOISTURE CURING" polyurethane resin is a single component, oil free, transparent coating, which dries quickly by a combination of solvent release, and polymerization initiated by both moisture in the atmosphere and/or the addition of catalyst. When cured, NI-12 is resilient, extremely abrasive resistant, and superior to most resin systems available today.

II. TYPICAL USES

A. Commercial, Industrial and Residential Flooring

1. Seamless Flooring

2. Hardwood Floor Coating

3. Concrete Floor Coating - Dust-proofing

 

III. ADVANTAGES AND LIMITATIONS

A. ADVANTAGES

1. Fast Dry

2. High Gloss

3. Exceptional Holdout Qualities

4. Abrasion resistance

5. Good Adhesion

6. Water Resistance

7. Resistance to Many Solvents

8. Resistance To Grease And Staining

9. Resistance To Mild Acids And Alkalis

B. LIMITATIONS

1. NI-12 should not be applied at temperatures below 50° F.

2. Solvent Release: NI-12 contains an aromatic solvent that evaporates during its cure. This solvent should be dispersed from the area by adequate ventilation.

3. Ambering: NI-12 will amber slightly with aging and direct sunlight. To reduce the degree of ambering, a top finish of NI-22 can be applied over NI-12.

 

IV. COLOR: Clear but can be pigmented using special pigments.  Contact Northern @ 401-821-2121

V. PHYSICAL ANALYSIS AND TECHNICAL DATA

A. TYPICAL ANALYSIS

 

% Solids 40± 1
Solvent Xylol
Viscosity (Brookfield) 120 cps
Color (Gardner) 1 max
% NCO 2.90
Weight/Gallon 8.1 lbs.
Flash Point 81° F.

B. POT LIFE: 30 to 45 minutes in the open container.

C. DRYING: The higher the humidity and the temperature, the faster NI-12 will cure. Under normal conditions of 60° F to 90° F and relative humidity above 35%, NI-12 can be walked on 5-12 hours after application. NI-12 can be buffed and re-coated when tack free to foil in 3-10 hours after application. NI-12 requires approximately one hour or less to "dry to touch", three to four hours to " harden" and about 7 days to cure.

(Air Dry 3 mil. wet film 40% solids, 50% Relative Humidity. 72° F.)

 

Set to touch 10 minutes
Surface Dry 45 minutes
Hard Dry 4 hours

D. HARDNESS: (Sward)

 

1 day 25
Hardness (Sward). 38
Ultimate 38

E. IMPACT RESISTANCE:

 

Impact Resistance

Direct

Reverse

Pass 160 inch pounds

Pass 140 inch pounds

F. TABER ABRASION RESISTANCE: Weight loss, 1000 gram load, 1000 cycles.

 

CS-10 Wheel 18 mg
CS-17 Wheel 28 mg

G. TENSILE STRENGTH

 

Tensile Strength 5000 psi

H. ELONGATION

 

Elongation 85%

I. IMMERSION TESTS 7 DAYS @ 125° F

 

  MEASURED VOLUME INCREASES (SWELLING)
Kerosene 0 (no effect)
Turpentine 0 (no effect)
High Flash Naphtha 25
Xylene 30
Benzene 45
Carbon Tetrachloride 35
Trichloroethylene 55
Methylene Chloride 50
Chlorobenzene 55
Freon-22 0 (no effect)
Nitropropane 35
DIBK 30
MIBK 55
Mek 40
Amyl Acetate 50
Cellosolve Acetate 50
Ethyl Acetate 75
Cellosolve Solvent 105
Dioxanne 110
Ethyl Alcohol 55
Ethylene Glycol 10
Glycerin 0 (no effect)
ASTM Fuel B 20
ASTM #3 Oil 10
Vegetable Oil 0 (no effect)

 

VI. APPLICATION

A. COVERAGE: On smooth non-porous surfaces, up to 650 square feet per gallon.

B. TOOLS: A good quality brush, lambs-wool applicator, or mohair roller, kept well filled, will insure an even coat.

C. PREPARATION: Surface must be thoroughly cleaned by sandblasting, wire brushing, scraping or other means to remove loose paint, mill scale, rust, etc. All grease, oil, or other matter must be removed by a suitable solvent. The first coat of NI-12 should be reduced to a 30% solid; second coat then can be applied at 40% level.

1. MASONRY: Surface must be clean, and dry, and free from grease, oil or other foreign matter. Concrete should be etched, neutralized and allowed to completely dry.

2. NEW WOOD: Surface must be clean, dry, and free from grease, oil or other foreign matter. No primer is required.

3. OLD WOOD: Clean and sandpaper surface.

D. APPLICATION:

1. Apply to surface with a good quality applicator.

2. Time between Coats: Any number of successive coats of NI-12 can be applied provided 24 hours have not transpired since the previous application.

E. CAUTION: Contains flammable liquids. Keep away from heat, sparks and fire. Do not leave container open. Use with adequate ventilation. Wear protective goggles and respirator. Avoid prolonged or repeated breathing of vapor. Avoid prolonged or repeated contact of liquid with skin. FOR INDUSTRY USE ONLY.

 

VII. PACKAGING: 55 and 30 gallon drums, 5-gallon pails

VIII. STORAGE DATA: NI-12 Aromatic Polyurethane should be stored in a cool, dry and safe area. Always rotate inventory, using oldest materials first. Shelf life is approximately 4 months in a factory sealed container.

 

Home ] Up ] Installation School ] Northern News Page ] Contact Info ]

logo.gif (4331 bytes)
        800-346-5543, 401-821-2121, Fax 401-821-9335